36000 BTU Dual Zone Ductless Mini Split Air Conditioner Heat Pump 18000 x 2
36000 BTU Dual Zone Ductless Mini Split AC. 16 SEER Efficiency w/ Heat Pump Technology. With a 36000 BTU combined Cooling / HEATING Capacity, this Dual Zone INVERTER mini split AC. Can cool or heat TWO separate zones (2 x 18000 BTU) for a total coverage area of 1600 ft² (800 ft² + 800 ft²). Inverter technology provides the benefits of low operation temps, rapid cooling / heating, as well as maximum energy efficiency. Pre-charged with eco-friendly R410A – 2 remotes included. 36000 BTU Cooling Capacity. 36000 BTU Heat Pump Capacity. INVERTER DC TECHNOLOGY: 16 SEER / 8.2 HSPF. Dual-Zone Setup (2 Air Handlers). Indoor Units – Air Handler. Digital, Multi-function LCD Remote Control. Filtration Screens – Multi Folds Evaporator. Dual Air Handlers for Multi-Zone Placement. INVERTER DC TECHNOLOGY: 16 SEER. Washable Filters – Biologically Active Enzyme. Low Startup Temps – MAXIMUM EFFICIENCY. Pre-charged w/ R-410A Freon for upto 50′ of lineset. Sleep Mode – 24 hour ON/OFF Timer – Memories. Enhanced Copper Coil – Wide Angle Air Spread. Over Current and Thermal Protection. Flexible, Quick Installation – Easy Operation. WHAT IS DC INVERTER? DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called “DC inverter” because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC’s bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically. Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained. BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 – 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires (NOT INCLUDED) to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables (NOT INCLUDED). The condensing unit comes pre-charged with R410A Freon however, procedures such as conducting leak tests etc. Are still important steps in ensuring proper functioning of a split AC. 5 Year Compressor – 2 Year on all other Parts Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not “plug-n-play” units that can be properly installed without certain tools any prior HVAC – electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Only ships to the lower 48 Contiguous United States. 25′ Lineset kit (1/4 x 1/2). Extend your 25′ lineset to a 50′ run with this 25′ of extra piping. 3.2 Gallons per Hour Rate – 120 or 220 VAC options. Mount your condenser at any height on an outdoor sidewall. View the Mini Split FAQ >. View the Mini Split Outline Diagram >. The item “36000 BTU Dual Zone Ductless Mini Split Air Conditioner Heat Pump 18000 x 2″ is in sale since Sunday, August 09, 2015. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners”. The seller is “thermospace_acs” and is located in Fort Lauderdale, Florida. This item can be shipped to United States.
- MPN: 36,000 BTU AC – Heat Pump: Mitsubishi Compressor
- Type: Split System
- Cooling BTU/Hr: 36000
- SEER: 16