110V 30MPa 4500PSI Air Compressor Pump PCP Electric High Pressure
110V 30MPa 4500PSI Air Compressor Pump PCP Electric High Pressure. User Manual(Before using, please read the Notice and Manual strictly). I: Please strictly follow this operating instructions for operation and use, otherwise it will cause the machine not to be used normally and damage the machine. Check/add oil above the red dot. Replace the breathing plug in the circle with the transport plug on the machine. Loosen the high pressure relief valve and the low pressure relief valve. Remember that the machine is unscrewed before start-up because the machine is starting with zero pressure. If it is not loosened, it will not start. After starting the machine, it will be tightened. When the inflator reaches the required pressure, loosen the pressure relief valve first, and then press the power off. Start cooling water circulation. Turn on the air pump power, start using. II:The installation method of separating water and oil. Unscrew hose and female head. Remove the separator and a white gasket inside the bag. Place the white gasket into the tapped hole in the separator. (White gasket must be installed, otherwise it will not be sealed, there is leakage phenomenon). Properly tightened to complete the installation. Check if the pressure relief valve is loose. Check if the overload protection function is activated. (Press the button in the figure below). Check if the motor’s foot is damaged by transportation. After power off, stir the fan with a screwdriver to turn the machine. If the above methods are tried but still not started, you could try the following method: removing the low pressure check valve. Be sure to follow the installation sequence when installing. The machine is equipped with an emergency high-pressure explosion-proof valve. The working principle is when the working pressure of the machine exceeds 30mpa, a very thin piece of copperr will be broken due to pressure. The broken copper piece cannot be repaired. At this time, a new one needs to be replaced. The following figure shows the location of the explosion-proof valve. Unscrew the explosion-proof valve screw. Insert the explosion-proof valve and tighten the explosion-proof valve screw. The machine can start normally but it cannot achieve higher pressure. At this time, the high pressure check valve needs to be cleaned. Clean up method Wrench loosen check valve screw. Remove the check valve and start the machine for 5 minutes. Clean the check valve hole and replace the check valve. Check valve installation sequence close-up. High Pressure 30Mpa Electric Compressor Pump PCP Electric Air Pump 110V BI. Connect 2 cold water pipes and connect them to the water pump. Note: the lower pipe connected to the water pump is water inlet; sinking pump is used in this product. The water pump should be immersed in water for using. Install the hose at the air outlet. Note: gasket is needed, or air leakage might exist. Install the pressure relief valve screw; pressure relief valve screw is installed at the pressure relief hole under the hose. The blow-down valve is installed at the. Drain outlet of the first air chamber block. Immerse the water pump in water and switch on the power. Connect the container need to be inflated. Screw up the screws of the blow-down valve and pressure relief valve. Switch on the power ant the machine operates. Note: when the machine is operating, the water must operate correspondingly, or the product might be damaged due to overheated, personal harm may even occur. After the inflation is completed, screw of the pressure relief valve should be firstly loosen, then the power is to be switched off, by doing so, high pressure. Air backlash caused due to sudden failure of power supply would be avoided, which could lengthen lifetime of the product, as well as discharge high pressure air in the machine. The product should be placed at a place that it couldnt be touched by children. Please do not use it in moist and flammable place. Please do not modify it arbitrarily, disassembling and repair by non-technical personnel is not allowed. Make sure the socket could withstand a current greater than 8A before using it, or the circuit might be burnt, the product might be damaged and the dangers may be caused due to overload of the socket. Please do not touch the head section after the machine was just being used, so as to not be burnt by high temperature. Please do not leave without authorized, or the product might be damaged by increasingly rising pressure, sustained overload motor, even halt due to the operation pressure has reached but it is not turned off timely. When it is used for inflating slightly larger container, the cooling water should be changed every 30 minutes, in this way, the cylinder temperature could be better controlled. The machine oil should be checked regularly, make sure the oil level is above the upper edge of the red point. If color of machine oil becomes dark and black, it should be changed in time. 46 wear resistant hydraulic oil. If the machine vibrates violently, please add pad or towel under the compressor. The compressor working, the cooling system can be working at the same time. The machine must be working with oil, so you must pay attention to the level of oil. Size: 36 18 37CM/14.27.114.6 INCH(L W H). Net Weight: 16.2KG/35.72LBS. Motor Power: 1.8KW. Charge pressure: 30MPA (it will automatic shut down when the pressure reach 30MPA). Air flow rate: 50L/MIN(13.2GPM). Working Pressure: 300BAR 30MPA 4500PSI. Cooling System: Water cooling. 1PC × 30Mpa Electric Compressor Pump. 2Pcs × Pressure Relief Screw. 1Set × Hose Female. 1PC × Water Pump. 1PC × Air Cock. 2Pcs × Water Pipe. 1PC × Wearing Parts. 5Pcs × Explosion-proof valve. 3Pcs × Rubber gasket. 2 Bags × Air filter cotton pad. 1 × English Manual. All products are quality checked. If your item is defective after 30 days, you can still send it back to us. We will send you a new one after receiving the default item. The item “110V 30MPa 4500PSI Air Compressor Pump PCP Electric High Pressure” is in sale since Saturday, May 11, 2019. This item is in the category “Business & Industrial\Hydraulics, Pneumatics, Pumps & Plumbing\Pumps & Pump Accessories\Other Pumps”. The seller is “online_us_warehouse” and is located in CA&NJ. This item can be shipped to United States.
- MPN: Does Not Apply
- Brand: Unbranded
- Introduction:: CA&NJ